Radon-Resistant New Construction

Roughing in a radon system before the slab is poured costs a fraction of retrofitting one later, and it makes activation a one-hour job if a post-occupancy test comes back high.

What the problem is

New homes are not inherently low-radon. Tighter building envelopes actually reduce natural air exchange, so soil gas that enters has less opportunity to dilute. The difference with new construction is opportunity: while the ground is open and the slab is unpoured, the entire soil-gas pathway can be controlled for a small fraction of what a retrofit costs.

How to know if you need it

  • You are building anywhere in New Mexico, where geology commonly produces elevated results.
  • Neighboring homes or the subdivision have tested high.
  • You are building a home with a basement or a walk-out lower level.
  • You want the option to activate a system later without cutting a finished slab.

The five features of a radon-resistant build

  1. 1Gas-permeable layer: 4 inches of clean, coarse aggregate beneath the slab so soil gas can move to a single collection point.
  2. 2Vapor retarder: heavy polyethylene sheeting over the aggregate, seams lapped and sealed.
  3. 3Sealing and caulking: all slab penetrations, control joints, and the floor-wall joint sealed.
  4. 4Vent pipe: a 3- or 4-inch PVC riser from a T-fitting in the aggregate, run through the building and out above the roofline.
  5. 5Junction box: an electrical box in the attic beside the vent pipe so a fan can be added later without new wiring.
Schematic
PassiveStack effect only — varies with weatherActiveFan-driven — consistent, verifiable reduction
Passive vs active systems. A passive system relies on natural stack effect through a vertical pipe. An active system adds a continuously running fan, producing far larger and more consistent reduction.

Process and construction sequencing

Construction stageRadon work
Sub-grade prepVerify clean aggregate depth and grading
Before slab pourSet the T-fitting, membrane, and riser stub
FramingRoute the vent pipe through chases to the attic
Rough electricalInstall the junction box adjacent to the pipe
Drywall / finishSeal penetrations, label the pipe
After occupancyTest; activate with a fan only if the result warrants it

Expected timeline

The rough-in adds hours, not days, and happens inside stages the builder is already performing. Activation later — adding a fan to an existing riser and junction box — is typically a 1–2 hour visit followed by a verification test.

What affects the cost

  • Slab area and number of risers.
  • Distance from the collection point to the roof termination.
  • Whether the aggregate layer already meets specification.
  • Coordination with the framing and electrical schedule.
  • Activation later adds the fan, electrical connection, and verification test.

What happens after occupancy

Test the finished home. A passive system alone reduces radon in many houses but not all — the stack effect that drives it is weak in mild weather. If the test comes back at or above 4.0 pCi/L, adding a fan converts the passive stack into an active system and almost always resolves it. Retest after activation, then every two years.

Not sure where to start? Call and ask.

We will walk you through testing, what your result means, and what a system for your home would involve — no pressure either way.