Radon service

Radon System Repair & Upgrades

An existing system that is silent, leaking, or simply not lowering the number is a fixable problem — usually a fan, a seal, or a design that needs one more suction point.

What the problem is

Radon systems are simple and durable, but they are not permanent. Fans wear out. Pipe joints crack from UV exposure or settlement. Sealed cracks open again as a slab moves. And some systems were under-designed from the start — installed with one suction point where the soil needed three. Because nothing about a failing radon system is obvious from inside the house, failures often go unnoticed for years.

How to know if your system needs attention

  • The manometer liquid is level on both sides — the fan is not moving air.
  • The fan is audibly grinding, rattling, or has gone silent.
  • A recent test still reads at or above 4.0 pCi/L despite an installed system.
  • The exterior pipe is cracked, chalky, or discolored from sun exposure.
  • The exhaust terminates below the roofline or near a window.
  • The fan is mounted in a basement or in living space, which is not permitted for the pressurized side of the system.
  • The system is more than 10 years old and has never been serviced.

How the system is diagnosed

  1. 1Manometer reading is compared against the value recorded at installation.
  2. 2Fan operation, amperage, and noise are checked.
  3. 3The full pipe run is inspected for cracks, disconnected joints, sags holding condensate, and improper termination.
  4. 4Seals at the floor-wall joint, sump lid, and penetrations are re-inspected.
  5. 5Sub-slab communication is re-measured if performance was always marginal.
  6. 6A short-term test establishes the current indoor level.

What the repair process looks like

FindingTypical fix
Failed fan, sound system otherwiseReplace the fan with a correctly sized unit
Manometer shows suction but levels stay highAdd a suction point or upsize the fan
Cracked or UV-damaged exterior pipeReplace the affected run and re-support it
Improper terminationExtend the exhaust above the roofline, away from openings
Fan located inside conditioned spaceRelocate to attic, garage attic, or exterior
Reopened slab cracksRe-seal joints and penetrations

Expected timeline

  • Fan replacement: 1–2 hours.
  • Pipe repair or re-routing: half a day.
  • Adding a suction point: half to a full day.
  • Verification test afterward: 48 hours, starting 24 hours after restart.

What affects the cost

  • Fan model and static pressure required.
  • Accessibility of the fan and pipe location.
  • How much of the original pipe run can be reused.
  • Whether additional suction points or electrical work are needed.

What happens after the repair

Every repair ends the same way a new install does: 24 hours of runtime, then a 48-hour verification test, then documentation of the new manometer reading so future checks have a baseline. If a repair cannot bring the home under the action level, we will tell you plainly that the design — not the fan — is the limiting factor.