Post-Mitigation Verification Testing

A mitigation system is unproven until it is measured. Verification testing closes the loop with a documented result you can hand to a buyer, a lender, or your own peace of mind.

What the problem is

A radon system that looks correct is not the same as a radon system that works. Suction can be insufficient for the soil, a suction point can be poorly placed, an unsealed sump or floor-wall joint can short-circuit the vacuum, or the fan can be under-sized. None of these are visible. Only a measurement after the system runs tells you what actually happened to the concentration in the house.

When verification testing is needed

  • Immediately after any new mitigation system is installed.
  • After a fan replacement or a change to the pipe routing.
  • After a system repair or the addition of a suction point.
  • When a buyer or lender requires documentation that a system is effective.
  • Every two years as a routine confirmation that performance has held.

How the test is performed

  1. 1The system runs continuously for at least 24 hours before the test begins.
  2. 2Closed-house conditions are established 12 hours in advance.
  3. 3A continuous radon monitor is placed on the lowest lived-in level, in the same general area as the original test where possible.
  4. 4The measurement runs a minimum of 48 hours with hourly logging.
  5. 5The report compares pre- and post-mitigation values and records fan operation and manometer reading.

Expected timeline

StepTiming
System runtime before testing24 hours minimum
Closed-house period12 hours before start
Measurement48 hours
Report deliveredSame day the monitor is retrieved

What result to expect

A properly designed active sub-slab system in a typical home should bring the level well below 4.0 pCi/L, and most land under 2.0 pCi/L. If the post-mitigation number is still elevated, the honest answer is that the design needs revision — commonly an additional suction point, a higher-capacity fan, or sealing that was missed.

EPA radon action levels

Scale shown in picocuries per liter (pCi/L).

0.4 outdoor avg1.3 US indoor avg2.0 consider action4.0 EPA action level10+

Green is at or below the typical US indoor average. Amber is the range where the EPA suggests considering mitigation. Red is at or above the 4.0 pCi/L action level, where the EPA recommends fixing the home.

What affects the cost

  • Whether the test is bundled with the installation or ordered separately.
  • Number of test locations for multi-foundation homes.
  • Continuous monitor versus lab-analyzed passive device.

What happens after the test

You receive a document that states the pre-mitigation level, the post-mitigation level, the device used, and the test conditions. Keep it with your home records — it is the single most useful document you can hand a future buyer, and it is what turns 'there is a system' into 'the system works.'

Not sure where to start? Call and ask.

We will walk you through testing, what your result means, and what a system for your home would involve — no pressure either way.